Initial commit: Linux kernel 4.19 for Unplugged OS

This commit is contained in:
ziv committed 2025-10-06 13:52:42 +00:00
commit d30235b04c
80519 files changed
+35800681

No files matched your search

@@ -0,0 +1,14 @@
* AT91 CAN *
Required properties:
- compatible: Should be "atmel,at91sam9263-can" or "atmel,at91sam9x5-can"
- reg: Should contain CAN controller registers location and length
- interrupts: Should contain IRQ line for the CAN controller
Example:
can0: can@f000c000 {
compatible = "atmel,at91sam9x5-can";
reg = <0xf000c000 0x300>;
interrupts = <40 4 5>
};
@@ -0,0 +1,65 @@
Bosch C_CAN/D_CAN controller Device Tree Bindings
-------------------------------------------------
Required properties:
- compatible : Should be "bosch,c_can" for C_CAN controllers and
"bosch,d_can" for D_CAN controllers.
Can be "ti,dra7-d_can", "ti,am3352-d_can" or
"ti,am4372-d_can".
- reg : physical base address and size of the C_CAN/D_CAN
registers map
- interrupts : property with a value describing the interrupt
number
The following are mandatory properties for DRA7x, AM33xx and AM43xx SoCs only:
- ti,hwmods : Must be "d_can<n>" or "c_can<n>", n being the
instance number
The following are mandatory properties for Keystone 2 66AK2G SoCs only:
- power-domains : Should contain a phandle to a PM domain provider node
and an args specifier containing the DCAN device id
value. This property is as per the binding,
Documentation/devicetree/bindings/soc/ti/sci-pm-domain.txt
- clocks : CAN functional clock phandle. This property is as per the
binding,
Documentation/devicetree/bindings/clock/ti,sci-clk.txt
Optional properties:
- syscon-raminit : Handle to system control region that contains the
RAMINIT register, register offset to the RAMINIT
register and the CAN instance number (0 offset).
Note: "ti,hwmods" field is used to fetch the base address and irq
resources from TI, omap hwmod data base during device registration.
Future plan is to migrate hwmod data base contents into device tree
blob so that, all the required data will be used from device tree dts
file.
Example:
Step1: SoC common .dtsi file
dcan1: d_can@481d0000 {
compatible = "bosch,d_can";
reg = <0x481d0000 0x2000>;
interrupts = <55>;
interrupt-parent = <&intc>;
status = "disabled";
};
(or)
dcan1: d_can@481d0000 {
compatible = "bosch,d_can";
ti,hwmods = "d_can1";
reg = <0x481d0000 0x2000>;
interrupts = <55>;
interrupt-parent = <&intc>;
status = "disabled";
};
Step 2: board specific .dts file
&dcan1 {
status = "okay";
};
@@ -0,0 +1,24 @@
Generic CAN transceiver Device Tree binding
------------------------------
CAN transceiver typically limits the max speed in standard CAN and CAN FD
modes. Typically these limitations are static and the transceivers themselves
provide no way to detect this limitation at runtime. For this situation,
the "can-transceiver" node can be used.
Required Properties:
max-bitrate: a positive non 0 value that determines the max
speed that CAN/CAN-FD can run. Any other value
will be ignored.
Examples:
Based on Texas Instrument's TCAN1042HGV CAN Transceiver
m_can0 {
....
can-transceiver {
max-bitrate = <5000000>;
};
...
};
@@ -0,0 +1,53 @@
Memory mapped Bosch CC770 and Intel AN82527 CAN controller
Note: The CC770 is a CAN controller from Bosch, which is 100%
compatible with the old AN82527 from Intel, but with "bugs" being fixed.
Required properties:
- compatible : should be "bosch,cc770" for the CC770 and "intc,82527"
for the AN82527.
- reg : should specify the chip select, address offset and size required
to map the registers of the controller. The size is usually 0x80.
- interrupts : property with a value describing the interrupt source
(number and sensitivity) required for the controller.
Optional properties:
- bosch,external-clock-frequency : frequency of the external oscillator
clock in Hz. Note that the internal clock frequency used by the
controller is half of that value. If not specified, a default
value of 16000000 (16 MHz) is used.
- bosch,clock-out-frequency : slock frequency in Hz on the CLKOUT pin.
If not specified or if the specified value is 0, the CLKOUT pin
will be disabled.
- bosch,slew-rate : slew rate of the CLKOUT signal. If not specified,
a resonable value will be calculated.
- bosch,disconnect-rx0-input : see data sheet.
- bosch,disconnect-rx1-input : see data sheet.
- bosch,disconnect-tx1-output : see data sheet.
- bosch,polarity-dominant : see data sheet.
- bosch,divide-memory-clock : see data sheet.
- bosch,iso-low-speed-mux : see data sheet.
For further information, please have a look to the CC770 or AN82527.
Examples:
can@3,100 {
compatible = "bosch,cc770";
reg = <3 0x100 0x80>;
interrupts = <2 0>;
interrupt-parent = <&mpic>;
bosch,external-clock-frequency = <16000000>;
};
@@ -0,0 +1,35 @@
Flexcan CAN controller on Freescale's ARM and PowerPC system-on-a-chip (SOC).
Required properties:
- compatible : Should be "fsl,<processor>-flexcan"
An implementation should also claim any of the following compatibles
that it is fully backwards compatible with:
- fsl,p1010-flexcan
- reg : Offset and length of the register set for this device
- interrupts : Interrupt tuple for this device
Optional properties:
- clock-frequency : The oscillator frequency driving the flexcan device
- xceiver-supply: Regulator that powers the CAN transceiver
- big-endian: This means the registers of FlexCAN controller are big endian.
This is optional property.i.e. if this property is not present in
device tree node then controller is assumed to be little endian.
if this property is present then controller is assumed to be big
endian.
Example:
can@1c000 {
compatible = "fsl,p1010-flexcan";
reg = <0x1c000 0x1000>;
interrupts = <48 0x2>;
interrupt-parent = <&mpic>;
clock-frequency = <200000000>; // filled in by bootloader
};
@@ -0,0 +1,28 @@
Aeroflex Gaisler GRCAN and GRHCAN CAN controllers.
The GRCAN and CRHCAN CAN controllers are available in the GRLIB VHDL IP core
library.
Note: These properties are built from the AMBA plug&play in a Leon SPARC system
(the ordinary environment for GRCAN and GRHCAN). There are no dts files for
sparc.
Required properties:
- name : Should be "GAISLER_GRCAN", "01_03d", "GAISLER_GRHCAN" or "01_034"
- reg : Address and length of the register set for the device
- freq : Frequency of the external oscillator clock in Hz (the frequency of
the amba bus in the ordinary case)
- interrupts : Interrupt number for this device
Optional properties:
- systemid : If not present or if the value of the least significant 16 bits
of this 32-bit property is smaller than GRCAN_TXBUG_SAFE_GRLIB_VERSION
a bug workaround is activated.
For further information look in the documentation for the GLIB IP core library:
http://www.gaisler.com/products/grlib/grip.pdf
@@ -0,0 +1,23 @@
* Holt HI-311X stand-alone CAN controller device tree bindings
Required properties:
- compatible: Should be one of the following:
- "holt,hi3110" for HI-3110
- reg: SPI chip select.
- clocks: The clock feeding the CAN controller.
- interrupts: Should contain IRQ line for the CAN controller.
Optional properties:
- vdd-supply: Regulator that powers the CAN controller.
- xceiver-supply: Regulator that powers the CAN transceiver.
Example:
can0: can@1 {
compatible = "holt,hi3110";
reg = <1>;
clocks = <&clk32m>;
interrupt-parent = <&gpio4>;
interrupts = <13 IRQ_TYPE_LEVEL_HIGH>;
vdd-supply = <&reg5v0>;
xceiver-supply = <&reg5v0>;
};
@@ -0,0 +1,15 @@
IFI CANFD controller
--------------------
Required properties:
- compatible: Should be "ifi,canfd-1.0"
- reg: Should contain CAN controller registers location and length
- interrupts: Should contain IRQ line for the CAN controller
Example:
canfd0: canfd@ff220000 {
compatible = "ifi,canfd-1.0";
reg = <0xff220000 0x00001000>;
interrupts = <0 43 0>;
};
@@ -0,0 +1,75 @@
Bosch MCAN controller Device Tree Bindings
-------------------------------------------------
Required properties:
- compatible : Should be "bosch,m_can" for M_CAN controllers
- reg : physical base address and size of the M_CAN
registers map and Message RAM
- reg-names : Should be "m_can" and "message_ram"
- interrupts : Should be the interrupt number of M_CAN interrupt
line 0 and line 1, could be same if sharing
the same interrupt.
- interrupt-names : Should contain "int0" and "int1"
- clocks : Clocks used by controller, should be host clock
and CAN clock.
- clock-names : Should contain "hclk" and "cclk"
- pinctrl-<n> : Pinctrl states as described in bindings/pinctrl/pinctrl-bindings.txt
- pinctrl-names : Names corresponding to the numbered pinctrl states
- bosch,mram-cfg : Message RAM configuration data.
Multiple M_CAN instances can share the same Message
RAM and each element(e.g Rx FIFO or Tx Buffer and etc)
number in Message RAM is also configurable,
so this property is telling driver how the shared or
private Message RAM are used by this M_CAN controller.
The format should be as follows:
<offset sidf_elems xidf_elems rxf0_elems rxf1_elems
rxb_elems txe_elems txb_elems>
The 'offset' is an address offset of the Message RAM
where the following elements start from. This is
usually set to 0x0 if you're using a private Message
RAM. The remain cells are used to specify how many
elements are used for each FIFO/Buffer.
M_CAN includes the following elements according to user manual:
11-bit Filter 0-128 elements / 0-128 words
29-bit Filter 0-64 elements / 0-128 words
Rx FIFO 0 0-64 elements / 0-1152 words
Rx FIFO 1 0-64 elements / 0-1152 words
Rx Buffers 0-64 elements / 0-1152 words
Tx Event FIFO 0-32 elements / 0-64 words
Tx Buffers 0-32 elements / 0-576 words
Please refer to 2.4.1 Message RAM Configuration in
Bosch M_CAN user manual for details.
Optional Subnode:
- can-transceiver : Can-transceiver subnode describing maximum speed
that can be used for CAN/CAN-FD modes. See
Documentation/devicetree/bindings/net/can/can-transceiver.txt
for details.
Example:
SoC dtsi:
m_can1: can@20e8000 {
compatible = "bosch,m_can";
reg = <0x020e8000 0x4000>, <0x02298000 0x4000>;
reg-names = "m_can", "message_ram";
interrupts = <0 114 0x04>,
<0 114 0x04>;
interrupt-names = "int0", "int1";
clocks = <&clks IMX6SX_CLK_CANFD>,
<&clks IMX6SX_CLK_CANFD>;
clock-names = "hclk", "cclk";
bosch,mram-cfg = <0x0 0 0 32 0 0 0 1>;
};
Board dts:
&m_can1 {
pinctrl-names = "default";
pinctrl-0 = <&pinctrl_m_can1>;
status = "enabled";
can-transceiver {
max-bitrate = <5000000>;
};
};
@@ -0,0 +1,25 @@
* Microchip MCP251X stand-alone CAN controller device tree bindings
Required properties:
- compatible: Should be one of the following:
- "microchip,mcp2510" for MCP2510.
- "microchip,mcp2515" for MCP2515.
- "microchip,mcp25625" for MCP25625.
- reg: SPI chip select.
- clocks: The clock feeding the CAN controller.
- interrupts: Should contain IRQ line for the CAN controller.
Optional properties:
- vdd-supply: Regulator that powers the CAN controller.
- xceiver-supply: Regulator that powers the CAN transceiver.
Example:
can0: can@1 {
compatible = "microchip,mcp2515";
reg = <1>;
clocks = <&clk24m>;
interrupt-parent = <&gpio4>;
interrupts = <13 0x2>;
vdd-supply = <&reg5v0>;
xceiver-supply = <&reg5v0>;
};
@@ -0,0 +1,53 @@
CAN Device Tree Bindings
------------------------
(c) 2006-2009 Secret Lab Technologies Ltd
Grant Likely <grant.likely@secretlab.ca>
fsl,mpc5200-mscan nodes
-----------------------
In addition to the required compatible-, reg- and interrupt-properties, you can
also specify which clock source shall be used for the controller:
- fsl,mscan-clock-source : a string describing the clock source. Valid values
are: "ip" for ip bus clock
"ref" for reference clock (XTAL)
"ref" is default in case this property is not
present.
fsl,mpc5121-mscan nodes
-----------------------
In addition to the required compatible-, reg- and interrupt-properties, you can
also specify which clock source and divider shall be used for the controller:
- fsl,mscan-clock-source : a string describing the clock source. Valid values
are: "ip" for ip bus clock
"ref" for reference clock
"sys" for system clock
If this property is not present, an optimal CAN
clock source and frequency based on the system
clock will be selected. If this is not possible,
the reference clock will be used.
- fsl,mscan-clock-divider: for the reference and system clock, an additional
clock divider can be specified. By default, a
value of 1 is used.
Note that the MPC5121 Rev. 1 processor is not supported.
Examples:
can@1300 {
compatible = "fsl,mpc5121-mscan";
interrupts = <12 0x8>;
interrupt-parent = <&ipic>;
reg = <0x1300 0x80>;
};
can@1380 {
compatible = "fsl,mpc5121-mscan";
interrupts = <13 0x8>;
interrupt-parent = <&ipic>;
reg = <0x1380 0x80>;
fsl,mscan-clock-source = "ref";
fsl,mscan-clock-divider = <3>;
};
@@ -0,0 +1,68 @@
Renesas R-Car CAN controller Device Tree Bindings
-------------------------------------------------
Required properties:
- compatible: "renesas,can-r8a7743" if CAN controller is a part of R8A7743 SoC.
"renesas,can-r8a7745" if CAN controller is a part of R8A7745 SoC.
"renesas,can-r8a7778" if CAN controller is a part of R8A7778 SoC.
"renesas,can-r8a7779" if CAN controller is a part of R8A7779 SoC.
"renesas,can-r8a7790" if CAN controller is a part of R8A7790 SoC.
"renesas,can-r8a7791" if CAN controller is a part of R8A7791 SoC.
"renesas,can-r8a7792" if CAN controller is a part of R8A7792 SoC.
"renesas,can-r8a7793" if CAN controller is a part of R8A7793 SoC.
"renesas,can-r8a7794" if CAN controller is a part of R8A7794 SoC.
"renesas,can-r8a7795" if CAN controller is a part of R8A7795 SoC.
"renesas,can-r8a7796" if CAN controller is a part of R8A7796 SoC.
"renesas,rcar-gen1-can" for a generic R-Car Gen1 compatible device.
"renesas,rcar-gen2-can" for a generic R-Car Gen2 or RZ/G1
compatible device.
"renesas,rcar-gen3-can" for a generic R-Car Gen3 compatible device.
When compatible with the generic version, nodes must list the
SoC-specific version corresponding to the platform first
followed by the generic version.
- reg: physical base address and size of the R-Car CAN register map.
- interrupts: interrupt specifier for the sole interrupt.
- clocks: phandles and clock specifiers for 3 CAN clock inputs.
- clock-names: 3 clock input name strings: "clkp1", "clkp2", "can_clk".
- pinctrl-0: pin control group to be used for this controller.
- pinctrl-names: must be "default".
Required properties for "renesas,can-r8a7795" and "renesas,can-r8a7796"
compatible:
In R8A7795 and R8A7796 SoCs, "clkp2" can be CANFD clock. This is a div6 clock
and can be used by both CAN and CAN FD controller at the same time. It needs to
be scaled to maximum frequency if any of these controllers use it. This is done
using the below properties:
- assigned-clocks: phandle of clkp2(CANFD) clock.
- assigned-clock-rates: maximum frequency of this clock.
Optional properties:
- renesas,can-clock-select: R-Car CAN Clock Source Select. Valid values are:
<0x0> (default) : Peripheral clock (clkp1)
<0x1> : Peripheral clock (clkp2)
<0x3> : Externally input clock
Example
-------
SoC common .dtsi file:
can0: can@e6e80000 {
compatible = "renesas,can-r8a7791", "renesas,rcar-gen2-can";
reg = <0 0xe6e80000 0 0x1000>;
interrupts = <0 186 IRQ_TYPE_LEVEL_HIGH>;
clocks = <&mstp9_clks R8A7791_CLK_RCAN0>,
<&cpg_clocks R8A7791_CLK_RCAN>, <&can_clk>;
clock-names = "clkp1", "clkp2", "can_clk";
status = "disabled";
};
Board specific .dts file:
&can0 {
pinctrl-0 = <&can0_pins>;
pinctrl-names = "default";
status = "okay";
};
@@ -0,0 +1,100 @@
Renesas R-Car CAN FD controller Device Tree Bindings
----------------------------------------------------
Required properties:
- compatible: Must contain one or more of the following:
- "renesas,rcar-gen3-canfd" for R-Car Gen3 compatible controller.
- "renesas,r8a7795-canfd" for R8A7795 (R-Car H3) compatible controller.
- "renesas,r8a7796-canfd" for R8A7796 (R-Car M3-W) compatible controller.
- "renesas,r8a77970-canfd" for R8A77970 (R-Car V3M) compatible controller.
- "renesas,r8a77980-canfd" for R8A77980 (R-Car V3H) compatible controller.
When compatible with the generic version, nodes must list the
SoC-specific version corresponding to the platform first, followed by the
family-specific and/or generic versions.
- reg: physical base address and size of the R-Car CAN FD register map.
- interrupts: interrupt specifiers for the Channel & Global interrupts
- clocks: phandles and clock specifiers for 3 clock inputs.
- clock-names: 3 clock input name strings: "fck", "canfd", "can_clk".
- pinctrl-0: pin control group to be used for this controller.
- pinctrl-names: must be "default".
Required child nodes:
The controller supports two channels and each is represented as a child node.
The name of the child nodes are "channel0" and "channel1" respectively. Each
child node supports the "status" property only, which is used to
enable/disable the respective channel.
Required properties for "renesas,r8a7795-canfd" and "renesas,r8a7796-canfd"
compatible:
In R8A7795 and R8A7796 SoCs, canfd clock is a div6 clock and can be used by both
CAN and CAN FD controller at the same time. It needs to be scaled to maximum
frequency if any of these controllers use it. This is done using the below
properties:
- assigned-clocks: phandle of canfd clock.
- assigned-clock-rates: maximum frequency of this clock.
Optional property:
The controller can operate in either CAN FD only mode (default) or
Classical CAN only mode. The mode is global to both the channels. In order to
enable the later, define the following optional property.
- renesas,no-can-fd: puts the controller in Classical CAN only mode.
Example
-------
SoC common .dtsi file:
canfd: can@e66c0000 {
compatible = "renesas,r8a7795-canfd",
"renesas,rcar-gen3-canfd";
reg = <0 0xe66c0000 0 0x8000>;
interrupts = <GIC_SPI 29 IRQ_TYPE_LEVEL_HIGH>,
<GIC_SPI 30 IRQ_TYPE_LEVEL_HIGH>;
clocks = <&cpg CPG_MOD 914>,
<&cpg CPG_CORE R8A7795_CLK_CANFD>,
<&can_clk>;
clock-names = "fck", "canfd", "can_clk";
assigned-clocks = <&cpg CPG_CORE R8A7795_CLK_CANFD>;
assigned-clock-rates = <40000000>;
power-domains = <&cpg>;
status = "disabled";
channel0 {
status = "disabled";
};
channel1 {
status = "disabled";
};
};
Board specific .dts file:
E.g. below enables Channel 1 alone in the board in Classical CAN only mode.
&canfd {
pinctrl-0 = <&canfd1_pins>;
pinctrl-names = "default";
renesas,no-can-fd;
status = "okay";
channel1 {
status = "okay";
};
};
E.g. below enables Channel 0 alone in the board using External clock
as fCAN clock.
&canfd {
pinctrl-0 = <&canfd0_pins &can_clk_pins>;
pinctrl-names = "default";
status = "okay";
channel0 {
status = "okay";
};
};
@@ -0,0 +1,58 @@
Memory mapped SJA1000 CAN controller from NXP (formerly Philips)
Required properties:
- compatible : should be one of "nxp,sja1000", "technologic,sja1000".
- reg : should specify the chip select, address offset and size required
to map the registers of the SJA1000. The size is usually 0x80.
- interrupts: property with a value describing the interrupt source
(number and sensitivity) required for the SJA1000.
Optional properties:
- reg-io-width : Specify the size (in bytes) of the IO accesses that
should be performed on the device. Valid value is 1, 2 or 4.
This property is ignored for technologic version.
Default to 1 (8 bits).
- nxp,external-clock-frequency : Frequency of the external oscillator
clock in Hz. Note that the internal clock frequency used by the
SJA1000 is half of that value. If not specified, a default value
of 16000000 (16 MHz) is used.
- nxp,tx-output-mode : operation mode of the TX output control logic:
<0x0> : bi-phase output mode
<0x1> : normal output mode (default)
<0x2> : test output mode
<0x3> : clock output mode
- nxp,tx-output-config : TX output pin configuration:
<0x01> : TX0 invert
<0x02> : TX0 pull-down (default)
<0x04> : TX0 pull-up
<0x06> : TX0 push-pull
<0x08> : TX1 invert
<0x10> : TX1 pull-down
<0x20> : TX1 pull-up
<0x30> : TX1 push-pull
- nxp,clock-out-frequency : clock frequency in Hz on the CLKOUT pin.
If not specified or if the specified value is 0, the CLKOUT pin
will be disabled.
- nxp,no-comparator-bypass : Allows to disable the CAN input comparator.
For further information, please have a look to the SJA1000 data sheet.
Examples:
can@3,100 {
compatible = "nxp,sja1000";
reg = <3 0x100 0x80>;
interrupts = <2 0>;
interrupt-parent = <&mpic>;
nxp,external-clock-frequency = <16000000>;
};
@@ -0,0 +1,36 @@
Allwinner A10/A20 CAN controller Device Tree Bindings
-----------------------------------------------------
Required properties:
- compatible: "allwinner,sun4i-a10-can"
- reg: physical base address and size of the Allwinner A10/A20 CAN register map.
- interrupts: interrupt specifier for the sole interrupt.
- clock: phandle and clock specifier.
Example
-------
SoC common .dtsi file:
can0_pins_a: can0@0 {
allwinner,pins = "PH20","PH21";
allwinner,function = "can";
allwinner,drive = <0>;
allwinner,pull = <0>;
};
...
can0: can@1c2bc00 {
compatible = "allwinner,sun4i-a10-can";
reg = <0x01c2bc00 0x400>;
interrupts = <0 26 4>;
clocks = <&apb1_gates 4>;
status = "disabled";
};
Board specific .dts file:
can0: can@1c2bc00 {
pinctrl-names = "default";
pinctrl-0 = <&can0_pins_a>;
status = "okay";
};
@@ -0,0 +1,32 @@
Texas Instruments High End CAN Controller (HECC)
================================================
This file provides information, what the device node
for the hecc interface contains.
Required properties:
- compatible: "ti,am3517-hecc"
- reg: addresses and lengths of the register spaces for 'hecc', 'hecc-ram'
and 'mbx'
- reg-names :"hecc", "hecc-ram", "mbx"
- interrupts: interrupt mapping for the hecc interrupts sources
- clocks: clock phandles (see clock bindings for details)
Optional properties:
- ti,use-hecc1int: if provided configures HECC to produce all interrupts
on HECC1INT interrupt line. By default HECC0INT interrupt
line will be used.
- xceiver-supply: regulator that powers the CAN transceiver
Example:
For am3517evm board:
hecc: can@5c050000 {
compatible = "ti,am3517-hecc";
reg = <0x5c050000 0x80>,
<0x5c053000 0x180>,
<0x5c052000 0x200>;
reg-names = "hecc", "hecc-ram", "mbx";
interrupts = <24>;
clocks = <&hecc_ck>;
};
@@ -0,0 +1,60 @@
Xilinx Axi CAN/Zynq CANPS controller Device Tree Bindings
---------------------------------------------------------
Required properties:
- compatible : Should be:
- "xlnx,zynq-can-1.0" for Zynq CAN controllers
- "xlnx,axi-can-1.00.a" for Axi CAN controllers
- "xlnx,canfd-1.0" for CAN FD controllers
- reg : Physical base address and size of the controller
registers map.
- interrupts : Property with a value describing the interrupt
number.
- clock-names : List of input clock names
- "can_clk", "pclk" (For CANPS),
- "can_clk", "s_axi_aclk" (For AXI CAN and CAN FD).
(See clock bindings for details).
- clocks : Clock phandles (see clock bindings for details).
- tx-fifo-depth : Can Tx fifo depth (Zynq, Axi CAN).
- rx-fifo-depth : Can Rx fifo depth (Zynq, Axi CAN, CAN FD in
sequential Rx mode).
- tx-mailbox-count : Can Tx mailbox buffer count (CAN FD).
- rx-mailbox-count : Can Rx mailbox buffer count (CAN FD in mailbox Rx
mode).
Example:
For Zynq CANPS Dts file:
zynq_can_0: can@e0008000 {
compatible = "xlnx,zynq-can-1.0";
clocks = <&clkc 19>, <&clkc 36>;
clock-names = "can_clk", "pclk";
reg = <0xe0008000 0x1000>;
interrupts = <0 28 4>;
interrupt-parent = <&intc>;
tx-fifo-depth = <0x40>;
rx-fifo-depth = <0x40>;
};
For Axi CAN Dts file:
axi_can_0: axi-can@40000000 {
compatible = "xlnx,axi-can-1.00.a";
clocks = <&clkc 0>, <&clkc 1>;
clock-names = "can_clk","s_axi_aclk" ;
reg = <0x40000000 0x10000>;
interrupt-parent = <&intc>;
interrupts = <0 59 1>;
tx-fifo-depth = <0x40>;
rx-fifo-depth = <0x40>;
};
For CAN FD Dts file:
canfd_0: canfd@40000000 {
compatible = "xlnx,canfd-1.0";
clocks = <&clkc 0>, <&clkc 1>;
clock-names = "can_clk", "s_axi_aclk";
reg = <0x40000000 0x2000>;
interrupt-parent = <&intc>;
interrupts = <0 59 1>;
tx-mailbox-count = <0x20>;
rx-fifo-depth = <0x20>;
};