.TH SG_READCAP "8" "January 2020" "sg3_utils\-1.45" SG3_UTILS
|
|
.SH NAME
|
|
sg_readcap \- send SCSI READ CAPACITY command
|
|
.SH SYNOPSIS
|
|
.B sg_readcap
|
|
[\fI\-\-16\fR] [\fI\-\-brief\fR] [\fI\-\-help\fR] [\fI\-\-hex\fR]
|
|
[\fI\-\-lba=LBA\fR] [\fI\-\-long\fR] [\fI\-\-pmi\fR] [\fI\-\-raw\fR]
|
|
[\fI\-\-readonly\fR] [\fI\-\-verbose\fR] [\fI\-\-version\fR] [\fI\-\-zbc\fR]
|
|
\fIDEVICE\fR
|
|
.PP
|
|
.B sg_readcap
|
|
[\fI\-16\fR] [\fI\-b\fR] [\fI\-h\fR] [\fI\-H\fR] [\fI\-lba=LBA\fR]
|
|
[\fI\-pmi\fR] [\fI\-r\fR] [\fI\-R\fR] [\fI\-v\fR] [\fI\-V\fR] [\fI\-z\fR]
|
|
\fIDEVICE\fR
|
|
.SH DESCRIPTION
|
|
.\" Add any additional description here
|
|
.PP
|
|
The normal action of the SCSI READ CAPACITY command is to fetch the number
|
|
of blocks (and block size) from the \fIDEVICE\fR.
|
|
.PP
|
|
The SCSI READ CAPACITY command (both 10 and 16 byte cdbs) actually yield
|
|
the block address of the last block and the block size. The number of
|
|
blocks is thus one plus the block address of the last block (as blocks
|
|
are counted origin zero (i.e. starting at block zero)). This is the source
|
|
of many "off by one" errors.
|
|
.PP
|
|
The READ CAPACITY(16) response provides additional information not found in
|
|
the READ CAPACITY(10) response. This includes protection and logical block
|
|
provisioning information, plus the number of logical blocks per physical
|
|
block. So even though the media size may not exceed what READ CAPACITY(10)
|
|
can show, it may still be useful to examine the response to READ
|
|
CAPACITY(16). Sadly there are horrible SCSI command set implementations in
|
|
the wild that crash when the READ CAPACITY(16) command is sent to them.
|
|
.PP
|
|
Device capacity is the product of the number of blocks by the block size.
|
|
This utility outputs this figure in bytes, MiB (1048576 bytes per MiB),
|
|
GB (1000000000 bytes per GB) and, if large enough, TB (1000 GB).
|
|
.PP
|
|
If sg_readcap is called without the \fI\-\-long\fR option then the 10 byte
|
|
cdb version (i.e. READ CAPACITY (10)) is sent to the \fIDEVICE\fR. If the
|
|
number of blocks in the response is reported as
|
|
0xffffffff (i.e. (2**32 \- 1) ) and the \fI\-\-hex\fR option has not been
|
|
given, then READ CAPACITY (16) is called and its response is output.
|
|
.PP
|
|
This utility supports two command line syntaxes, the preferred one is
|
|
shown first in the synopsis and explained in this section. A later section
|
|
on the old command line syntax outlines the second group of options.
|
|
.SH OPTIONS
|
|
Arguments to long options are mandatory for short options as well.
|
|
The options are arranged in alphabetical order based on the long
|
|
option name.
|
|
.TP
|
|
\fB\-\-16\fR
|
|
Use the 16 byte cdb variant of the READ CAPACITY command. See the '\-\-long'
|
|
option.
|
|
\fB\-b\fR, \fB\-\-brief\fR
|
|
outputs two hex numbers (prefixed with '0x' and space separated)
|
|
to stdout. The first number is the maximum number of blocks on the
|
|
device (which is one plus the lba of the last accessible block). The
|
|
second number is the size in bytes of each block. If the operation fails
|
|
then "0x0 0x0" is written to stdout.
|
|
.TP
|
|
\fB\-h\fR, \fB\-\-help\fR
|
|
print out the usage message then exit.
|
|
.TP
|
|
\fB\-H\fR, \fB\-\-hex\fR
|
|
output the response to the READ CAPACITY command (either the 10 or 16
|
|
byte cdb variant) in ASCII hexadecimal on stdout.
|
|
.TP
|
|
\fB\-L\fR, \fB\-\-lba\fR=\fILBA\fR
|
|
used in conjunction with \fI\-\-pmi\fR option. This variant of READ CAPACITY
|
|
will yield the last block address after \fILBA\fR prior to a delay. For a
|
|
disk, given a \fILBA\fR it yields the highest numbered block on the same
|
|
cylinder (i.e. before the heads need to move). \fILBA\fR is assumed to be
|
|
decimal unless prefixed by "0x" or it has a trailing "h". Defaults to 0.
|
|
This option was made obsolete in SBC\-3 revision 26.
|
|
.TP
|
|
\fB\-l\fR, \fB\-\-long\fR
|
|
Use the 16 byte cdb variant of the READ CAPACITY command. The default
|
|
action is to use the 10 byte cdb variant which limits the maximum
|
|
block address to (2**32 \- 2). When a 10 byte cdb READ CAPACITY command
|
|
is used on a device whose size is too large then a last block address
|
|
of 0xffffffff is returned (if the device complies with SBC\-2 or later).
|
|
.TP
|
|
\fB\-O\fR, \fB\-\-old\fR
|
|
Switch to older style options. Please use as first option.
|
|
.TP
|
|
\fB\-p\fR, \fB\-\-pmi\fR
|
|
partial medium indicator: for finding the next block address prior to
|
|
some delay (e.g. head movement). In the absence of this option, the
|
|
total number of blocks and the block size of the device are output.
|
|
Used in conjunction with the \fI\-\-lba=LBA\fR option. This option was
|
|
made obsolete in SBC\-3 revision 26.
|
|
.TP
|
|
\fB\-r\fR, \fB\-\-raw\fR
|
|
output response in binary to stdout.
|
|
.TP
|
|
\fB\-R\fR, \fB\-\-readonly\fR
|
|
open the \fIDEVICE\fR read\-only (e.g. in Unix with the O_RDONLY flag).
|
|
The default for READ CAPACITY(16) is to open it read\-write. The default
|
|
for READ CAPACITY(10) is to open it read\-only so this option does not
|
|
change anything for this case.
|
|
.TP
|
|
\fB\-v\fR, \fB\-\-verbose\fR
|
|
increase level of verbosity. Can be used multiple times.
|
|
.TP
|
|
\fB\-V\fR, \fB\-\-version\fR
|
|
outputs version string then exits.
|
|
.TP
|
|
\fB\-z\fR, \fB\-\-zbc\fR
|
|
additionally prints out the extra ZBC field (RC_BASIS) in the READ CAPACITY
|
|
response. Using the option implicitly sets the \fI\-\-16\fR option.
|
|
.SH NOTES
|
|
The response to READ CAPACITY(16) contains a LBPRZ bit in the SBC\-3
|
|
standard (ANSI INCITS 514\-2014). There was also a LBPRZ bit with the same
|
|
meaning in the Logical block provisioning VPD page (0xb2). Then somewhat
|
|
confusingly T10 expanded the LBPRZ bit to a 3 bit field in SBC\-4 draft
|
|
revision 7, but only in the LB provisioning VPD page. The reason for the
|
|
expansion was to report a new "provisioning initialization pattern"
|
|
state (when an unmapped logical block is read). The new state has been
|
|
assigned LBPRZ=2 in the VPD page and it re\-uses LBPRZ=0 in the READ
|
|
CAPACITY(16) response. LBPRZ=1 retains the same meaning for both variants,
|
|
namely that a block of zeroes will be returned when an unmapped logical block
|
|
is read.
|
|
.SH EXIT STATUS
|
|
The exit status of sg_readcap is 0 when it is successful. Otherwise see
|
|
the sg3_utils(8) man page.
|
|
.SH OLDER COMMAND LINE OPTIONS
|
|
The options in this section were the only ones available prior to sg3_utils
|
|
version 1.23 . Since then this utility defaults to the newer command line
|
|
options which can be overridden by using \fI\-\-old\fR (or \fI\-O\fR) as the
|
|
first option. See the ENVIRONMENT VARIABLES section for another way to
|
|
force the use of these older command line options.
|
|
.TP
|
|
\fB\-16\fR
|
|
Use the 16 byte cdb variant of the READ CAPACITY command.
|
|
Equivalent to \fI\-\-long\fR in the main description.
|
|
.TP
|
|
\fB\-b\fR
|
|
utility outputs two hex numbers (prefixed with '0x' and space separated) to
|
|
stdout. The first number is the maximum number of blocks on the device (which
|
|
is one plus the lba of the last accessible block). The second number is the
|
|
size of each block. If the operation fails then "0x0 0x0" is written to
|
|
stdout. Equivalent to \fI\-\-brief\fR in the main description.
|
|
.TP
|
|
\fB\-h\fR
|
|
output the usage message then exit. Giving the \fI\-?\fR option also outputs
|
|
the usage message then exits.
|
|
.TP
|
|
\fB\-H\fR
|
|
output the response to the READ CAPACITY command (either the 10 or 16
|
|
byte cdb variant) in ASCII hexadecimal on stdout.
|
|
.TP
|
|
\fB\-lba\fR=\fILBA\fR
|
|
used in conjunction with \fI\-pmi\fR option. This variant of READ CAPACITY
|
|
will yield the last block address after \fILBA\fR prior to a delay.
|
|
Equivalent to \fI\-\-lba=LBA\fR in the main description.
|
|
.TP
|
|
\fB-N\fR, \fB\-\-new\fR
|
|
Switch to the newer style options.
|
|
.TP
|
|
\fB\-pmi\fR
|
|
partial medium indicator: for finding the next block address prior to
|
|
some delay (e.g. head movement). In the absence of this switch, the
|
|
total number of blocks and the block size of the device are output.
|
|
Equivalent to \fI\-\-pmi\fR in the main description.
|
|
.TP
|
|
\fB\-r\fR
|
|
output response in binary (to stdout).
|
|
.TP
|
|
\fB\-R\fR
|
|
Equivalent to \fI\-\-readonly\fR in the main description.
|
|
.TP
|
|
\fB\-v\fR
|
|
verbose: print out cdb of issued commands prior to execution. '\-vv'
|
|
and '\-vvv' are also accepted yielding greater verbosity.
|
|
.TP
|
|
\fB\-V\fR
|
|
outputs version string then exits.
|
|
.TP
|
|
\fB\-z\fR
|
|
Equivalent to \fI\-\-zbc\fR in the main description.
|
|
.SH ENVIRONMENT VARIABLES
|
|
Since sg3_utils version 1.23 the environment variable SG3_UTILS_OLD_OPTS
|
|
can be given. When it is present this utility will expect the older command
|
|
line options. So the presence of this environment variable is equivalent to
|
|
using \fI\-\-old\fR (or \fI\-O\fR) as the first command line option.
|
|
.SH AUTHORS
|
|
Written by Douglas Gilbert
|
|
.SH COPYRIGHT
|
|
Copyright \(co 1999\-2020 Douglas Gilbert
|
|
.br
|
|
This software is distributed under the GPL version 2. There is NO
|
|
warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.
|
|